mask name

Function

The mask name command creates an alarm filtering table.

The undo mask name command deletes the alarm filtering table.

By default, no alarm filtering table.

Format

mask name mask-name

undo mask name mask-name

Parameters

Parameter Description Value
mask-name

Specifies the name of an alarm filtering table.

The value is a string of 1 to 31 characters, spaces not supported.

Views

Alarm management view

Default Level

3: Management level

Task Name and Operations

Task Name Operations
fault-mgr write

Usage Guidelines

Usage Scenario

You can run the mask name command to filter out alarms that you are not concerned about. You need to create an alarm filtering table before configuring an alarm filtering table.

Configuration Impact

After the mask name command is run, if the specified alarm filtering table does not exist, the system creates one and the relevant view is displayed; if the specified alarm filtering table exists, the table view is displayed.

Follow-up Procedure

Alarms to be filtered out or alarm attributes, such as the alarm severity, alarm time, alarm-relevant feature, are defined in the created alarm filtering table. After the alarm filtering table is bound to a terminal, alarms reported from the terminal are to be filtered out. The alarms that match the entries in the alarm filtering table are not reported.

Example

# Create an alarm filtering table named mask1.
<HUAWEI> system-view
[~HUAWEI] alarm
[~HUAWEI-alarm] mask name mask1
[*HUAWEI-alarm-mask-mask1]
Copyright © Huawei Technologies Co., Ltd.