condition syslog pattern

Function

The condition syslog pattern command configures Syslogs as the triggering condition for a maintenance assistant.

The undo condition command cancels the configuration.

By default, no triggering condition is configured for a maintenance assistant.

Format

condition syslog pattern reg-express [ occurs occur-number [ period period-value ] ]

Parameters

Parameter Description Value
reg-express

Specifies the formula expression of a Syslog.

The value is a string of 1 to 255 case-sensitive characters, spaces not supported.

occurs occur-number

Specifies the number of times a Syslog is generated.

The value is an integer ranging from 1 to 32.

period period-value

Specifies the period during which a Syslog is generated.

The value is an integer ranging from 1 to 4294967295.

Views

Maintenance assistant task view

Default Level

3: Management level

Task Name and Operations

Task Name Operations
ops write

Usage Guidelines

Usage Scenario

After a maintenance assistant is created, a triggering condition must be specified so that the maintenance assistant can be automatically operated as long as the triggering condition is met.

To trigger a maintenance assistant based on a Syslog, run the condition syslog pattern command.

Prerequisites

The assistant command has been run in the system view to create a maintenance assistant.

Precautions

A maintenance assistant can be configured with only one triggering condition.

Example

# Configure the maintenance assistant to be triggered based on Syslog hwClockChanged.
<HUAWEI> system-view
[~HUAWEI] ops
[~HUAWEI-ops] assistant task
[*HUAWEI-ops-assistant-task] condition syslog pattern .*hwClockChanged.*