The clock tod protocol command configures the protocol type that the packets carrying TOD information abide by.
The undo clock tod protocol command deletes the protocol type that the packets carrying TOD information abide by.
By default, the protocol type is ubx.
Parameter | Description | Value |
---|---|---|
ubx |
Specifies ubx as the protocol type that the packets carrying TOD information abide by. |
- |
nmea |
Specifies nmea as the protocol type that the packets carrying TOD information abide by. |
- |
ccsa |
Specifies ccsa as the protocol type that the packets carrying TOD information abide by. |
- |
g-8271 |
Specifies g-8271 as the protocol type that the packets carrying TOD information abide by. |
- |
Usage Scenario
By default, the packets carrying TOD information abide by the UBX protocol.
Based on the signal type of an external BITS clock, you can run the clock tod protocol command to configure the protocol type that the packets carrying TOD information abide by.Precautions
The TOD protocols at both ends of the 1PPS+ToD signal of the external time interface must be set to the same mode. Otherwise, the 1PPS+ToD signal cannot be used.
After the clock tod protocol ccsa command is configured, the input and output signals of the TOD convert the second pulse status of external time signals to the clock class according to the ccsa standard.