display bip8-status

Function

The display bip8-status command displays the BIP-8 alarm status and threshold.

Format

display bip8-status

Parameters

None

Views

100GE interface view, 40GE interface view, 50GE interface view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
device-mgr read

Usage Guidelines

Usage Scenario

To check the BIP-8 alarm status and threshold, run the display bip8-status command.

Example

The actual command output varies according to the device. The command output here is only an example.

# Display the BIP-8 alarm status and threshold on 100GE 0/1/0.
<HUAWEI> system-view
[~HUAWEI] interface 100GE 0/1/0
[~HUAWEI-100GE0/1/0] display bip8-status
bip8    status      :false
bip8-sd threshold   :6
bip8-sd alarm status:false
# Display the BIP-8 alarm status and threshold on 40GE 0/1/16.
<HUAWEI> system-view
[~HUAWEI] interface 40GE 0/1/16
[~HUAWEI-40GE0/1/16] display bip8-status
bip8    status      :false
bip8-sd threshold   :6
bip8-sd alarm status:false
Table 1 Description of the display bip8-status command output
Item Description
bip8 status

Whether the current interface has bip8 verification errors.

  • true.
  • false.
bip8-sd threshold

Exponent of the BIP-8 alarm threshold on the interface. If the exponent is 6, the alarm threshold is 10-6.

bip8-sd alarm status

BIP-8 alarm status of the interface.

  • true: Alarm exists.
  • false: No alarms exist.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.