The display disaster-recovery command displays disaster recovery configurations on a vBRAS-UP.
This command is supported only on the NetEngine 8000 F1A.
Usage Scenario
To check disaster recovery configurations on a vBRAS-UP, run the display disaster-recovery command. Before you run the command, ensure that disaster recovery configurations, such as disaster recovery groups, master/backup role, and source and destination IP addresses, have been configured on the vBRAS-CP.
Precautions
In VS mode, this command is supported only by the admin VS.
The actual command output varies according to the device. The command output here is only an example.
<HUAWEI> system-view [~HUAWEI] display disaster-recovery ---------------------------------------------------------- Configuration in the CP CP : 1.1.1.1 Master : 1.1.1.1 Slave : 2.2.2.2 Openflow_cp :3.3.3.3 Vxlan_cp :1.1.1.1 Priority : 100 ---------------------------------------------------------- Configuration in the CP CP : 2.2.2.2 Master : 1.1.1.1 Slave : 2.2.2.2 Openflow_cp :3.3.3.3 Vxlan_cp :1.1.1.1 Priority : 100 ---------------------------------------------------------- Negotiation result Master : 1.1.1.1 Slave : 2.2.2.2 ----------------------------------------------------------
| Item | Description |
|---|---|
| CP | vBRAS-CP that manages the vBRAS-UP. |
| Master | IP address of the master vBRAS-CP. |
| Slave | IP address of the backup vBRAS-CP. |
| Openflow_cp | IP address of an control channel. |
| Vxlan_cp | IP address of a protocol channel. |
| Priority | Priority of the vBRAS-CP's master/backup role. |