display qos hard-pipe statistics interface outbound

Function

The display qos hard-pipe statistics interface outbound command displays hard pipe statistics about outgoing traffic on the PW-side or AC-side hard pipe interface.

This command is supported only on the NetEngine 8000 F1A.

Format

display qos hard-pipe statistics interface interface-name outbound

display qos hard-pipe statistics interface { interface-name | interface-type interface-number } outbound

Parameters

Parameter Description Value
interface-name

Specifies an interface name.

-

interface-type interface-number

Specifies an interface type and number.

-

Views

All views

Default Level

1: Monitoring level

Task Name and Operations

Task Name Operations
qos read

Usage Guidelines

Usage Scenario

To check hard pipe statistics of outgoing traffic on a PW-side or AC-side hard pipe interface, run the display qos hard-pipe statistics command.

Example

The actual command output varies according to the device. The command output here is only an example.

# Display hard pipe statistics of outgoing traffic on GE 0/1/8.
<HUAWEI> display qos hard-pipe statistics interface gigabitethernet0/1/8 outbound
GigabitEthernet0/1/8 outbound traffic statistics:
Pass: 0 packets,0 bytes
Discard: 0 packets, 0 bytes
Last 5 minutes pass rate: 0 pps, 0 bps
Last 5 minutes discard rate: 0 pps, 0 bps
Table 1 Description of the display qos hard-pipe statistics interface outbound command output
Item Description
GigabitEthernet

Interface name.

Pass

Number of forwarded packets or bytes.

Discard

Number of dropped packets or bytes.