The display transmission-alarm configuration command displays the alarm status and alarm statistics on an interface. If no alarm type is specified, alarms of all types on the interface are displayed.
This command is supported only on the NetEngine 8000 F1A.
The actual command output varies according to the device. The command output here is only an example.
<HUAWEI> display transmission-alarm configuration wan 0/1/0
Interface: wan0/1/0
Filter function: disable
Damping function: enabled
Suppress value: 999
Ceiling value: 6000
Reuse value: 500
OK half decay value: 500
NG half decay value: 1000
Item | Description |
---|---|
Filter function | Filtering function status:
|
Damping function | Indicates whether to enable the suppression function.
-Disable: The suppression function is disabled. |
Suppress value | Indicates the suppression threshold. |
Ceiling value | Indicates the ceiling threshold. |
Reuse value | Indicates the reuse threshold. |
OK half decay value | Indicates the half life when the alarm is cleared. |
NG half decay value | Indicates the half life when an alarm is generated. |
Interface | Interface name. |