display voltage

Function

The display voltage command displays the status and configuration of the voltage sensor.

Format

display voltage [ slot slot-id ]

display voltage ipu

display voltage slot slot-id pic pic-id

Parameters

Parameter Description Value
slot slot-id

Specifies a slot ID.

The value is a string of 1 to 49 case-sensitive characters, spaces not supported.

pic pic-id

Specifies a PIC ID.

The value is an integer that ranges from 0 to 16.

ipu

Ipu board.

-

Views

All views

Default Level

1: Monitoring level

Task Name and Operations

Task Name Operations
device-mgr read

Usage Guidelines

Usage Scenario

During routine maintenance or when a fault occurs on a device, you can run the display voltage command to check whether the voltage of the device is within a normal range and locate the fault.

Precautions

For the voltage scope in which the device works properly, refer to the Hardware Description. If the output of the display voltage command indicates that the current working voltage of the device is out of the scope, adjust the working voltage to ensure the proper running of the device.

For the voltage scope in which the device works properly, refer to the Hardware Description. If the output of the display voltage ipu command indicates that the current working voltage of the device is out of the scope, adjust the working voltage to ensure the proper running of the device.

Example

The actual command output varies according to the device. The command output here is only an example.

# Display the configuration, status, and value of the voltage sensor on the board in specific slot.
<HUAWEI> system-view
[~HUAWEI] display voltage slot 1
  Base-Board, Unit:V, Slot 1
-----------------------------------------------------------------------------------
PCB          I2C Addr Chl Status   Require MajorL FatalL MajorH FatalH Vlt(V) Ratio
-----------------------------------------------------------------------------------
XXXX         0   0    0   NORMAL   12.00   10.00  9.00   13.00  14.00  11.82  0.17
XXXX         1   0    1   NORMAL   12.00   10.00  9.00   13.00  14.00  11.88  0.17
XXXX         1   33   0   NORMAL   1.00    0.93   0.90   1.07   1.10   1.00   1.00
XXXX         1   33   1   NORMAL   1.00    0.90   0.87   1.07   1.10   1.01   1.00
XXXX         1   33   2   NORMAL   1.00    0.90   0.87   1.07   1.10   1.01   1.00
XXXX         1   33   3   NORMAL   1.00    0.80   0.75   1.07   1.10   0.96   1.00
XXXX         1   33   4   NORMAL   0.90    0.80   0.75   1.00   1.05   0.90   1.00
XXXX         1   33   5   NORMAL   1.00    0.93   0.90   1.07   1.10   0.99   1.00
XXXX         1   33   6   NORMAL   0.90    0.80   0.75   1.00   1.05   0.90   1.00
XXXX         1   33   7   NORMAL   1.50    1.40   1.35   1.61   1.65   1.53   1.00
XXXX         1   33   8   NORMAL   1.80    1.67   1.62   1.93   1.98   1.81   1.00
XXXX         1   33   9   NORMAL   1.20    1.12   1.08   1.28   1.32   1.21   1.00
XXXX         1   33   10  NORMAL   2.50    2.33   2.25   2.68   2.75   2.52   1.00
XXXX         1   33   11  NORMAL   1.00    0.80   0.75   1.07   1.10   0.94   1.00
XXXX         2   0    2   NORMAL   3.30    3.07   2.96   3.52   3.63   3.40   0.57
XXXX         3   0    3   NORMAL   5.00    4.20   3.80   5.80   6.20   5.12   0.40
XXXX         4   0    4   NORMAL   1.00    0.90   0.87   1.07   1.10   1.01   1.00
XXXX         5   0    5   NORMAL   0.75    0.65   0.60   0.85   0.90   0.77   1.00
---------------------------------------------------------------------
Table 1 Description of the display voltage command output
Item Description
Slot

position.

PCB

Type of the board.

I2C

ID of the voltage sensor.

Addr

Address of the voltage sensor.

Chl

Channel of the voltage sensor.

Status

Status of the voltage sensor.

Require

Required voltage value.

MajorL

Minor alarm about a low voltage. If the voltage falls below the threshold, the alarm is triggered.

MajorH

Minor alarm about a high voltage. If the voltage rises above the threshold, the alarm is triggered.

FatalL

Fatal alarm about a low voltage. If the voltage falls below the threshold, the device may work improperly or be damaged.

FatalH

Fatal alarm about a high voltage. If the voltage rises above the threshold, the device may work improperly or be damaged.

Ratio

Ratio of the output voltage detected by a voltage sensor to the actual voltage.

Vlt

Current voltage.

Unit

Unit.

Copyright © Huawei Technologies Co., Ltd.