Usage Scenario
During routine maintenance or when a fault occurs on a device, you can run the display voltage command to check whether the voltage of the device is within a normal range and locate the fault.
Precautions
For the voltage scope in which the device works properly, refer to the Hardware Description. If the output of the display voltage command indicates that the current working voltage of the device is out of the scope, adjust the working voltage to ensure the proper running of the device.
For the voltage scope in which the device works properly, refer to the Hardware Description. If the output of the display voltage ipu command indicates that the current working voltage of the device is out of the scope, adjust the working voltage to ensure the proper running of the device.The actual command output varies according to the device. The command output here is only an example.
<HUAWEI> system-view [~HUAWEI] display voltage slot 1 Base-Board, Unit:V, Slot 1 ----------------------------------------------------------------------------------- PCB I2C Addr Chl Status Require MajorL FatalL MajorH FatalH Vlt(V) Ratio ----------------------------------------------------------------------------------- XXXX 0 0 0 NORMAL 12.00 10.00 9.00 13.00 14.00 11.82 0.17 XXXX 1 0 1 NORMAL 12.00 10.00 9.00 13.00 14.00 11.88 0.17 XXXX 1 33 0 NORMAL 1.00 0.93 0.90 1.07 1.10 1.00 1.00 XXXX 1 33 1 NORMAL 1.00 0.90 0.87 1.07 1.10 1.01 1.00 XXXX 1 33 2 NORMAL 1.00 0.90 0.87 1.07 1.10 1.01 1.00 XXXX 1 33 3 NORMAL 1.00 0.80 0.75 1.07 1.10 0.96 1.00 XXXX 1 33 4 NORMAL 0.90 0.80 0.75 1.00 1.05 0.90 1.00 XXXX 1 33 5 NORMAL 1.00 0.93 0.90 1.07 1.10 0.99 1.00 XXXX 1 33 6 NORMAL 0.90 0.80 0.75 1.00 1.05 0.90 1.00 XXXX 1 33 7 NORMAL 1.50 1.40 1.35 1.61 1.65 1.53 1.00 XXXX 1 33 8 NORMAL 1.80 1.67 1.62 1.93 1.98 1.81 1.00 XXXX 1 33 9 NORMAL 1.20 1.12 1.08 1.28 1.32 1.21 1.00 XXXX 1 33 10 NORMAL 2.50 2.33 2.25 2.68 2.75 2.52 1.00 XXXX 1 33 11 NORMAL 1.00 0.80 0.75 1.07 1.10 0.94 1.00 XXXX 2 0 2 NORMAL 3.30 3.07 2.96 3.52 3.63 3.40 0.57 XXXX 3 0 3 NORMAL 5.00 4.20 3.80 5.80 6.20 5.12 0.40 XXXX 4 0 4 NORMAL 1.00 0.90 0.87 1.07 1.10 1.01 1.00 XXXX 5 0 5 NORMAL 0.75 0.65 0.60 0.85 0.90 0.77 1.00 ---------------------------------------------------------------------
Item | Description |
---|---|
Slot | position. |
PCB | Type of the board. |
I2C | ID of the voltage sensor. |
Addr | Address of the voltage sensor. |
Chl | Channel of the voltage sensor. |
Status | Status of the voltage sensor. |
Require | Required voltage value. |
MajorL | Minor alarm about a low voltage. If the voltage falls below the threshold, the alarm is triggered. |
MajorH | Minor alarm about a high voltage. If the voltage rises above the threshold, the alarm is triggered. |
FatalL | Fatal alarm about a low voltage. If the voltage falls below the threshold, the device may work improperly or be damaged. |
FatalH | Fatal alarm about a high voltage. If the voltage rises above the threshold, the device may work improperly or be damaged. |
Ratio | Ratio of the output voltage detected by a voltage sensor to the actual voltage. |
Vlt | Current voltage. |
Unit | Unit. |