The efm error-frame-period notification enable command enables EFM OAM to detect and notify its peer device of errored frames on an interface.
The undo efm error-frame-period notification enable command disables EFM OAM from detecting and notifying its peer device of errored frames on an interface.
By default, an interface is disabled from detecting and notifying its peer device of errored frames that EFM periodically detects.
Layer 2 100GE interface view, 100GE interface view, Layer 2 10GE interface view, 10GE interface view, 25GE-L2 view, 25GE interface view, 400GE-L2 view, 400GE interface view, Layer 2 40GE interface view, 40GE interface view, Layer 2 50GE interface view, 50GE interface view, FlexE interface view, Layer 2 GE interface view, GE optical interface view, GE interface view, GE electrical interface view
Usage Scenario
Fault detection on an Ethernet network is difficult when the physical connection on the network is not closed but network performance deteriorates gradually. Link monitoring is used to detect link layer faults in various environments. After EFM OAM link monitoring is configured, statistics about the physical layer data of the interface management module are queried to monitor the quality of the link connected to the current interface. EFM OAM link monitoring implements the following functions:
Prerequisites
EFM has been enabled on an interface using the efm enable command in the interface view.
<HUAWEI> system-view [~HUAWEI] efm enable [*HUAWEI] interface GigabitEthernet0/1/0 [*HUAWEI-GigabitEthernet0/1/0] efm enable [*HUAWEI-GigabitEthernet0/1/0] efm error-frame-period notification enable