The forward-alarm slot board flow input bandwidth usage-rate alarm on off command sets the alarm reporting and alarm clearance thresholds for input traffic on a board.
The forward-alarm slot board flow output bandwidth usage-rate alarm on off command sets the alarm reporting and alarm clearance thresholds for output traffic on a board.
The undo forward-alarm slot board flow alarm command restores the default alarm reporting and alarm clearance thresholds for traffic on a board.
By default, the alarm threshold is 80, and the clear alarm threshold is 75.
Parameter | Description | Value |
---|---|---|
slot-id |
Specifies the slot ID of a board. The value range varies according to device hardware. |
The value is a string of 1 to 15 case-sensitive characters, spaces not supported. |
on onrate |
Specifies the alarm reporting threshold. |
The value is an integer that ranges from 0 to 100. |
off offrate |
Specifies the alarm clearance threshold. |
The value is an integer that ranges from 0 to 99. |
Usage Scenario
To set the alarm reporting and alarm clearance thresholds for traffic on a board, run the forward-alarm slot board flow usage-rate alarm on off command. To restore the default alarm reporting and alarm clearance thresholds for traffic on a board, run the undo forward-alarm slot board flow alarm command.