forward-alarm packet reassembly resources alarm

Function

The forward-alarm packet reassembly resources alarm command sets the alarm reporting and alarm clearance thresholds for packet reassembly.

The undo forward-alarm packet reassembly resources alarm command restores the default alarm reporting and alarm clearance thresholds for packet reassembly.

By default, the alarm threshold is 90, and the clear alarm threshold is 80.

Format

forward-alarm slot slot-id packet reassembly resources usage-rate alarm on onrate off offrate

undo forward-alarm slot slot-id packet reassembly resources alarm

Parameters

Parameter Description Value
usage-rate

Usage rate.

-

on onrate

Specifies the alarm reporting threshold.

The value is an integer that ranges from 0 to 100.

off offrate

Specifies the alarm clearance threshold.

The value is an integer that ranges from 0 to 99.

slot slot-id

Specifies the slot ID of a board. The value range varies according to device hardware.

The value is a string of 1 to 15 case-sensitive characters, spaces not supported.

Views

System view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
cli write

Usage Guidelines

Usage Scenario

To set the alarm reporting and alarm clearance thresholds for packet reassembly, run the forward-alarm packet reassemblyresources usage-rate alarm on off command. To restore the default alarm reporting and alarm clearance thresholds for packet reassembly, run the undo forward-alarm packet reassembly resources usage-rate alarm command.

Example

# Set the alarm reporting and alarm clearance thresholds for packet reassembly of a specified board to 70 and 60, respectively.
<HUAWEI> system-view
[~HUAWEI] forward-alarm slot 1 packet reassembly resources usage-rate alarm on 70 off 60