The forward-alarm performance usage-rate alarm command sets the alarm reporting and alarm clearance thresholds for forwarding performance.
The undo forward-alarm performance usage-rate alarm command restores the default alarm reporting and alarm clearance thresholds for forwarding performance.
By default, the alarm threshold is 80, and the clear alarm threshold is 75.
Parameter | Description | Value |
---|---|---|
on onrate |
Specifies the alarm reporting threshold. |
The value is an integer that ranges from 0 to 100. |
off offrate |
Specifies the alarm clearance threshold. |
The value is an integer that ranges from 0 to 99. |
slot slot-id |
Specifies the slot ID of a board. The value range varies according to device hardware. |
The value is a string of 1 to 15 case-sensitive characters, spaces not supported. |
Usage Scenario
To set the alarm reporting and alarm clearance thresholds for forwarding performance, run the forward-alarm slot performance usage-rate alarm on off command. To restore the default alarm reporting and alarm clearance thresholds for forwarding performance, run the undo forward-alarm slot performance usage-rate alarm command.