forward-alarm performance usage-rate alarm

Function

The forward-alarm performance usage-rate alarm command sets the alarm reporting and alarm clearance thresholds for forwarding performance.

The undo forward-alarm performance usage-rate alarm command restores the default alarm reporting and alarm clearance thresholds for forwarding performance.

By default, the alarm threshold is 80, and the clear alarm threshold is 75.

Format

forward-alarm slot slot-id performance usage-rate alarm on onrate off offrate

undo forward-alarm slot slot-id performance usage-rate alarm

Parameters

Parameter Description Value
on onrate

Specifies the alarm reporting threshold.

The value is an integer that ranges from 0 to 100.

off offrate

Specifies the alarm clearance threshold.

The value is an integer that ranges from 0 to 99.

slot slot-id

Specifies the slot ID of a board. The value range varies according to device hardware.

The value is a string of 1 to 15 case-sensitive characters, spaces not supported.

Views

System view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
cli write

Usage Guidelines

Usage Scenario

To set the alarm reporting and alarm clearance thresholds for forwarding performance, run the forward-alarm slot performance usage-rate alarm on off command. To restore the default alarm reporting and alarm clearance thresholds for forwarding performance, run the undo forward-alarm slot performance usage-rate alarm command.

Example

# Set the alarm reporting and alarm clearance thresholds for forwarding performance of a specified board to 90 and 80, respectively.
<HUAWEI> system-view
[~HUAWEI] forward-alarm slot 1 performance usage-rate alarm on 90 off 80
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >