loop-detect trigger min-slot-uptime

Function

The loop-detect trigger min-slot-uptime command configures the minimum startup time for the interface boards.

The undo loop-detect trigger min-slot-uptime command restores the default minimum time for enabling the interface boards.

By default, the minimum time for enabling an interface board is 30 minutes.

Format

loop-detect trigger min-slot-uptime min-slot-uptime

undo loop-detect trigger min-slot-uptime [ min-slot-uptime ]

Parameters

Parameter Description Value
min-slot-uptime

Specifies the minimum time for enabling an interface board.

The value ranges from 1 to 100, in seconds. The default value is 30 minutes.

Views

System view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
vlan write

Usage Guidelines

Usage Scenario

To configure the minimum startup time for enabling the interface board, run the loop-detect trigger min-slot-uptime command. The minimum time is the threshold for proactive loop detection upon interface Up. The proactive loop detection upon interface Up function takes effect only when the interface Down time exceeds the threshold.

Example

# Set the minimum time for enabling an interface board to 15 minutes.
<HUAWEI> system-view
[~HUAWEI] loop-detect trigger min-slot-uptime 15