mask severity

Function

The mask severity command enables a device to filter out an alarm with specific severity.

The undo mask severity command disables a device to filter out an alarm with specific severity.

By default, alarms are not masked.

Format

mask severity Critical

mask severity Major

mask severity Minor

mask severity Warning

undo mask severity Critical

undo mask severity Major

undo mask severity Minor

undo mask severity Warning

Parameters

Parameter Description Value
Major

Specifies Major as the severity of an alarm.

-

Minor

Specifies Minor as the severity of an alarm.

-

Warning

Specifies Warning as the severity of an alarm.

-

Critical

Specifies Critical as the severity of an alarm.

-

Views

Alarm masking list view

Default Level

3: Management level

Task Name and Operations

Task Name Operations
fault-mgr write

Usage Guidelines

Usage Scenario

You can filter out alarms with specific severity that you are not concerned about.

Prerequisites

The alarm filtering table exists.

Configuration Impact

The mask severity command can be repeatedly run to filter out multiple alarms with different severity.

Example

# Define the alarms with the severity being Warning in the alarm filtering table named mask1.
<HUAWEI> system-view
[~HUAWEI] alarm
[~HUAWEI-alarm] mask name mask1
[*HUAWEI-alarm-mask-mask1] mask severity warning