The optical-module alarm-threshold standardization enable command enables alarm threshold standardization for optical modules.
The undo optical-module alarm-threshold standardization enable command cancels alarm threshold standardization for optical modules.
By default, alarm threshold standardization is disabled for optical modules.
Usage Scenario
To enable alarm threshold standardization for optical modules, run the optical-module threshold-standardization enable command. Enabling alarm threshold standardization implements optical power-related alarm threshold standardization and changes the mode of obtaining thresholds for sending and receiving optical power. If the optical-module threshold-standardization enable command is not run, thresholds are calculated based on data read from the optical module registers, which is the default mode of obtaining a threshold. If the optical-module threshold-standardization enable command is run, optical power thresholds use a standardized value that is calculated based on the optical module transmission distance and bandwidth.
Precautions
The optical-module threshold-standardization enable command configuration is effective only for interfaces that have optical-interface-equipped optical modules.
This command is supported only on the admin VS.