optical-module alarm-threshold standardization enable

Function

The optical-module alarm-threshold standardization enable command enables alarm threshold standardization for optical modules.

The undo optical-module alarm-threshold standardization enable command cancels alarm threshold standardization for optical modules.

By default, alarm threshold standardization is disabled for optical modules.

Format

optical-module alarm-threshold standardization enable

undo optical-module alarm-threshold standardization enable

Parameters

None

Views

System view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
system write

Usage Guidelines

Usage Scenario

To enable alarm threshold standardization for optical modules, run the optical-module threshold-standardization enable command. Enabling alarm threshold standardization implements optical power-related alarm threshold standardization and changes the mode of obtaining thresholds for sending and receiving optical power. If the optical-module threshold-standardization enable command is not run, thresholds are calculated based on data read from the optical module registers, which is the default mode of obtaining a threshold. If the optical-module threshold-standardization enable command is run, optical power thresholds use a standardized value that is calculated based on the optical module transmission distance and bandwidth.

Precautions

The optical-module threshold-standardization enable command configuration is effective only for interfaces that have optical-interface-equipped optical modules.

This command is supported only on the admin VS.

Example

# Enable alarm threshold standardization for optical modules.
<HUAWEI> system-view
[~HUAWEI] optical-module alarm-threshold standardization enable
Copyright © Huawei Technologies Co., Ltd.