port-alarm clear bip8-sd (interface view)

Function

The port-alarm clear bip8-sd command clears alarms generated on a physical port.

Format

port-alarm clear bip8-sd

Parameters

Parameter Description Value
bip8-sd

BIP8 signal degrade alarm.

-

Views

100GE interface view, 40GE interface view, 50GE interface view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
device-mgr write

Usage Guidelines

Usage Scenario

When the associated physical port is down after a CRC, SDH, receive, transmit, symbol alarm is generated on a port, the alarm cannot be recovered automatically. In that case, you can run this command to clear the alarm on the port. The port-alarm clear bip8-sd command clears alarms generated on a port and restores the port. The system does not save the configurations with this command. Therefore, configuration restoration is unnecessary.

Prerequisites

Run the port-alarm down (interface view) or port-alarm down (system view) command to enable the function to shut down the associated physical port when an alarm is generated.

Precautions

This command takes effect only when the corresponding alarm function is enabled. You can run the snmp-agent trap enable port command to enable the function to generate alarms for CRC, SDH, input, output, symbol errors on an interface.

Example

# Clear the bip8-sd alarm on the interface and restore the updown status of the interface.
<HUAWEI> system-view
[~HUAWEI] interface 100GE 0/1/0
[~HUAWEI-100GE0/1/0] port-alarm clear bip8-sd
Copyright ? Huawei Technologies Co., Ltd.
Copyright ? Huawei Technologies Co., Ltd.
< Previous topic Next topic >