The srv6-te flow-group-number threshold-alarm command configures an alarm threshold for the number of SRv6 TE flow groups. This configuration takes effect for all SRv6 TE flow groups.
The undo srv6-te flow-group-number threshold-alarm command restores the default alarm threshold for the number of SRv6 TE flow groups. This configuration takes effect for all SRv6 TE flow groups.
By default, the upper threshold is 80% and the lower threshold is 75%.
Parameter | Description | Value |
---|---|---|
lower-limit lowerLimitValue |
Specifies the lower threshold (default value: 75). |
The value is an integer ranging from 1 to 99, in percentage. |
upper-limit upperLimitValue |
Specifies the upper threshold (default value: 80). |
The value is an integer ranging from 2 to 100, in percentage. |
<HUAWEI> system-view [~HUAWEI] segment-routing ipv6 [*HUAWEI-segment-routing-ipv6] srv6-te flow-group-number threshold-alarm upper-limit 90 lower-limit 70