loss-measure single-ended-synthetic continual send interval

Function

The loss-measure single-ended-synthetic continual send interval command enables single-ended proactive SLM.

The undo loss-measure single-ended-synthetic continual send command disables single-ended proactive SLM.

By default, the function is disabled.

Format

loss-measure single-ended-synthetic continual send test-id test-id interval { 1000 | 10000 } [ sending-count count-value ] [ time-out timeout ] [ period period ]

undo loss-measure single-ended-synthetic continual send test-id test-id

Parameters

Parameter Description Value
test-id test-id

Specifies the ID.

The value is an integer ranging from 1 to 4294967295.

1000

Specifies the interval.

-

10000

Specifies the interval.

-

sending-count count-value

Specifies the times that synthetic loss measurements (SLM) are sent within each measurement period.

The value is an integer ranging from 1 to 1000. The default value is 10.

time-out timeout

Specifies the timeout period during which the device waits for a reply.

The value is an integer ranging from 1 to 10, in seconds. The default value is 5s.

period period

Specifies the interval at which statistics are collected.

The value is an integer ranging from 1 to 65535, in seconds. The default value is 900.

Views

MA view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
y1731 write

Usage Guidelines

Usage Scenario

To collect accurate frame loss statistics on a point-to-multipoint network, run the loss-measure single-ended-synthetic continual send command to enable single-ended proactive SLM.

Prerequisites

Ensure that the following commands have been run:

  • IEEE Standard 802.1ag-2007 of CFM has been specified using the cfm version standard command in the system view.
  • The Connectivity Fault Management (CFM) function has been enabled globally using the cfm enable (system view) command in the system view.
  • A Maintenance Domain (MD) has been created using the cfm md command in the system view.
  • A Maintenance Association (MA) has been created using the ma command in the MD view.
  • An inward-facing Maintenance Association End Point (MEP) has been created using the mep mep-id command in the MA view.
  • The local MEP has been enabled to send Continuity Check Message (CCM) to the RMEP in the MA using the mep ccm-send enable command in the MA view
  • The local MEP has been enabled to receive CCMs from the remote MEP in the same MA using the remote-mep ccm-receive enable command in the MA view.

Example

# Configure SLM with the test id of 1 and statistics collection interval of 1000s.
[~HUAWEI] mpls
[~HUAWEI-mpls] mpls l2vpn
[~HUAWEI-l2vpn] interface GigabitEthernet 0/1/9
[~HUAWEI-GigabitEthernet0/1/9] mpls l2vc 2.2.2.3 1001
[*HUAWEI-GigabitEthernet0/1/9] cfm enable
[*HUAWEI] cfm md md1
[*HUAWEI-md-md1] ma ma2
[*HUAWEI-md-md1-ma-ma2] map mpls l2vc 2.2.2.3 1001 raw
[*HUAWEI-md-md1-ma-ma2] mep mep-id 1 interface GigabitEthernet 0/1/9 inward
[*HUAWEI-md-md1-ma-ma2] test-id 1 mep 1 mac xxxx-xxxx-xxxx
[*HUAWEI-md-md1-ma-ma2] loss-measure single-ended-synthetic continual send test-id 1 interval 1000 sending-count 10 time-out 5
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >