mpls te bfd tunnel (MPLS view)

Function

The mpls te bfd tunnel command sets BFD for SR-MPLS TE parameters.

The undo mpls te bfd tunnel command restores the default configuration.

By default, after BFD for SR-MPLS TE is enabled, the minimum interval at which BFD packets are sent and the minimum interval at which BFD packets are received are 10 ms, and the detection multiplier is 3.

Format

mpls te bfd tunnel { min-tx-interval tx-interval | min-rx-interval rx-interval | detect-multiplier multiplier } *

undo mpls te bfd tunnel { min-tx-interval [ tx-interval ] | min-rx-interval [ rx-interval ] | detect-multiplier [ multiplier ] } *

Parameters

Parameter Description Value
min-tx-interval tx-interval

Specifies the minimum interval at which BFD packets are sent.

The value is an integer ranging from 3 to 20000, in milliseconds.

min-rx-interval rx-interval

Specifies the minimum interval at which BFD packets are received.

The value is an integer ranging from 3 to 20000, in milliseconds.

detect-multiplier multiplier

Specifies a BFD detection multiplier.

The value is an integer ranging from 3 to 50.

Views

MPLS view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
mpls-te write

Usage Guidelines

Usage Scenario

One-arm BFD for E2E SR-MPLS TE tunnel quickly detects faults on inter-AS E2E SR-MPLS TE tunnels and protects traffic on the E2E SR-MPLS TE tunnels. To set BFD for SR-MPLS TE parameters, run the mpls te bfd tunnel command.

Prerequisites

BFD has been enabled globally.

Example

# Set global one-arm BFD for SR-MPLS TE parameters.
<HUAWEI> system-view
[~HUAWEI] mpls lsr-id 1.1.1.1
[*HUAWEI] mpls
[*HUAWEI-mpls] mpls te
[*HUAWEI-mpls] mpls te bfd tunnel min-rx-interval 500 detect-multiplier 5