The mpls te bfd tunnel command sets BFD for SR-MPLS TE parameters.
The undo mpls te bfd tunnel command restores the default configuration.
By default, after BFD for SR-MPLS TE is enabled, the minimum interval at which BFD packets are sent and the minimum interval at which BFD packets are received are 10 ms, and the detection multiplier is 3.
Parameter | Description | Value |
---|---|---|
min-tx-interval tx-interval |
Specifies the minimum interval at which BFD packets are sent. |
The value is an integer ranging from 3 to 20000, in milliseconds. |
min-rx-interval rx-interval |
Specifies the minimum interval at which BFD packets are received. |
The value is an integer ranging from 3 to 20000, in milliseconds. |
detect-multiplier multiplier |
Specifies a BFD detection multiplier. |
The value is an integer ranging from 3 to 50. |