transceiver non-certified status-alarm enable

Function

The transceiver non-certified status-alarm enable command enables alarm reporting for non-certified optical module's status.

The undo transceiver non-certified status-alarm enable command enable alarm reporting for non-certified optical module's status.

By default, non-certified optical module's alarm is not reported.

Format

transceiver non-certified status-alarm enable

undo transceiver non-certified status-alarm enable

Parameters

None

Views

System view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
system write

Usage Guidelines

Usage Scenario

When a non-Huawei-certified optical module is installed on an interface, you can run transceiver non-certified status-alarm enable command to control whether to report the hwOpticalInvalid alarm.

Example

# Enable alarm reporting for unauthenticated optical module's status.
<HUAWEI> system-view
[~HUAWEI] transceiver non-certified status-alarm enable
Warning: This command enables the function of reporting status alarms of third-party optical modules. If a problem or defect occurs when a third-party optical module is used, Huawei does not take any responsibility. Continue? [Y/N]:y