transmission-alarm holdoff-timer (interface view)

Function

The transmission-alarm holdoff-timer command can enable the filtering function and set the filtering interval.

The undo transmission-alarm holdoff-timer command can disable the filtering function.

By default, the filtering function is disabled.

This command is supported only on the NetEngine 8000 F1A.

Format

transmission-alarm holdoff-timer [ holdoff-time ]

undo transmission-alarm holdoff-timer

Parameters

Parameter Description Value
holdoff-time

Indicates the interval for filtering alarms when the alarm is delayed.

The value is an integer that ranges from 20-10000 to milliseconds. The default value is 50 ms.

Views

10G WAN interface view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
device-mgr write

Usage Guidelines

Usage Scenario

If an interface is connected to a transmission device and the network is unstable, a large number of burr alarms are generated when the interface frequently alternates between up and down. If you want to ignore these alarms within a certain period, run the transmission-alarm holdoff-timer command to set an interval for filtering transmission alarms. After this command is run, the interface delays going up/down accordingly.

Prerequisites

Transmission alarm customization has been enabled on an interface.

Configuration Impact

The link setup speed of a 100 Gbit/s CFP2 DWDM optical module is slow (maximum 180s). Therefore, you are not advised to configure the Down suppression command.

Precautions

The value of the holdoff-time parameter varies with the flapping frequency of interfaces.

Example

# Set the alarm filtering interval on GigabitEthernet 0/1/0 to 100 milliseconds.
<HUAWEI> system-view
[~HUAWEI] interface GigabitEthernet 0/1/0
[~HUAWEI-GigabitEthernet 0/1/0] transmission-alarm holdoff-timer 100