FEI_COMM/3/INIT_ERROR

Message

FEI_COMM/3/INIT_ERROR: The [Stage] stage of component initialization fails because action [ActionName] is taken. ErrorCode=[ErrorCode].

In VS mode, this log is supported only by the admin VS.

Description

Component initialization failed at a specific stage due to the component's incorrect action.

Parameters

Parameter Name Parameter Meaning

Stage

Component creation phase ID

ActionName

Name of an abnormal action

ErrorCode

Error code of an initialization function execution error

Possible Causes

Cause 1: Forwarding control software was faulty.

Cause 2: Forwarding hardware was faulty.

Cause 3: Forwarding resources were insufficient.

Procedure

1. Run the reset slot slot-id command to reset the faulty board and check whether the board can be registered.

  • If yes, go to Step 3.
  • If the registration fails, go to Step 2.

2. Collect alarm, log, and configuration information and contact technical support engineers.

3. End.