L2-MULTICAST/2/QINQ_IF_BDW_EXD_TRAP

Message

L2-MULTICAST/2/QINQ_IF_BDW_EXD_TRAP: Exceed the bandwidth limit on multicast groups.(IfIndex=[IfIndex], IfName=[IfName], ConfiguredValue=[ConfiguredValue], CurrentMulticastGroup=[CurrentMulticastGroup], CurrentMulticastSource=[CurrentMulticastSource], PE-Vid=[PE-Vid], CE-Vid=[CE-Vid])

Description

The bandwidth of multicast groups on the sub-interface for QinQ VLAN tag termination reached the upper limit.

Parameters

Parameter Name Parameter Meaning

IfIndex

Indicates the QinQ interface index.

IfName

Indicates the QinQ interface name.

ConfiguredValue

Indicates the configured limit.

CurrentMulticastGroup

Indicates the current multicast group.

CurrentMulticastSource

Indicates the current multicast source.

PE-Vid

Indicates the outer VLAN tag.

CE-Vid

Indicates the inner VLAN tag.

Possible Causes

New multicast groups attempted to join the QinQ termination sub-interface when the bandwidth of multicast groups on the QinQ termination sub-interface reached or exceeded the configured bandwidth limit.

Procedure

1. Run the display l2-multicast limit command to check whether the configured bandwidth limit for multicast groups on the current QinQ termination sub-interface is smaller than or equal to the statistics.

  • If so, go to Step 2.
  • If not, go to Step 6.

2. Run the undo l2-multicast dynamic-group command to delete unneeded entries, and then check whether the alarm recurs.

  • If so, go to Step 3.
  • If not, go to Step 4.

3. Lower the configured bandwidth limit for multicast groups on the current QinQ termination sub-interface as required, and then check whether the alarm recurs.

  • If so, go to Step 4.
  • If not, go to Step 7.

4. Run the display l2-multicast limit command to check whether the configured bandwidth limit for multicast groups on the current QinQ termination sub-interface is too small.

  • If so, go to Step 5.
  • If not, go to Step 6.

5. Increase the configured bandwidth limit for multicast groups on the current QinQ termination sub-interface as required, and then check whether the alarm recurs.

  • If so, go to Step 6.
  • If not, go to Step 7.

6. Collect alarm information and configuration information, and then contact technical support personnel.

7. End.