CLKSYNC/4/SYNSTATUS: The synchronization status of the time source changed. (State=[State])
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
State |
Value of the time source synchronization status. The options are as follows:
|
Cause 1: The PTP function is running properly, and the device achieves time synchronization.
Cause 2: The link is faulty or the interface is Down. As a result, the device does not have a synchronized time source.
1. Check the synchronization status.
If the synchronization status is syn, this log message is informational only, and no action is required.
If the synchronization status is non-syn, go to Step 2.
2. Run the display device command to check whether the LPU is registered.
If the LPU cannot be registered, it indicates that the hardware of the LPU is faulty. In this case, replace the LPU.
If the LPU can be registered after being reset, it indicates that the software is faulty. In this case, go to Step 3.
3. Run the display ptp all config command to check whether the device configuration is correct.
If yes, go to Step 4.
If no, go to Step 5.
4. Configure the PTP function according to the PTP configuration manual. Check whether the fault is rectified.
If the alarm is cleared, go to Step 6.
If the alarm persists, go to Step 5.
5. Collect trap, log, and configuration information, and contact technical support.
6. End.