CLKSYNC/4/SRCSWITCH: The time source is switched from [LastSource] to [CurrentSource]. (hwPtpPortOldSourcePortNum=[hwPtpPortOldSourcePortNum], hwPtpPortSourcePortNum=[hwPtpPortSourcePortNum], hwPtpOldPortName=[hwPtpOldPortName], hwPtpPortName= [hwPtpPortName])
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
LastSource |
Original time source ID. |
CurrentSource |
ID of the current time source. |
hwPtpPortOldSourcePortNum |
Old port number of the tracing source. |
hwPtpPortSourcePortNum |
Port number of the traced clock source. |
hwPtpOldPortName |
Old name of the tracing source port. |
hwPtpPortName |
Name of the port that is tracing the clock source. |
1. Check whether the source switching is caused by the configuration information. If yes, modify the configuration information or do not perform any operation.
2. Ensure that the physical interface connected to the external clock source is up.
3. Ensure that PTP packets are correctly sent and received.
4. Ensure that the networking environment and related services support IEEE 1588v2 time synchronization.
5. If the switchover is abnormal, contact maintenance personnel to locate the fault.
6. Collect trap, log, and configuration information, and contact technical support.
7. End.