TWAMP/4/TWAMP_TWOWAY_JITTER_active

Message

TWAMP/4/TWAMP_TWOWAY_JITTER_active: The two-way jitter of the TWAMP test instance exceeded the upper threshold in three consecutive test intervals. (Test SessionId=[sessionId], Value=[Value], UpperLimitThreshold=[UpperLimitThreshold], LowerLimitThreshold=[LowerLimitThreshold], Sender IP=[sender-address], Reflector IP=[reflector-address], Sender Port=[sender-port], Reflector Port=[reflector-port], VPN Instance=[vpn-name])

Description

The two-way jitter of a TWAMP test instance exceeded the threshold in three consecutive measurement periods.

Parameters

Parameter Name Parameter Meaning

sessionId

TWAMP Light test session ID.

Value

Jitter value

UpperLimitThreshold

The jitter trigger-alarm threshold value.

LowerLimitThreshold

The clear-alarm jitter threshold value.

sender-address

IP address of the sender.

reflector-address

IP address of the reflector.

sender-port

Port number of the sender.

reflector-port

Port number of the reflector.

vpn-name

Indicates the VPN instance name.

Possible Causes

  • Cause 1: The network bandwidth usage reached or exceeded the preset bandwidth threshold.
  • Cause 2: The service traversed a large number of NEs.

Procedure

Cause 1: The network bandwidth usage reached or exceeded the preset bandwidth threshold.

1. Check whether the network bandwidth usage reached or exceeded the preset bandwidth threshold.

  • If yes, expand the capacity.
  • If not, go to step 2.

2. Collect alarm information and configuration information, and then contact technical support personnel.

Cause 2: The service traversed a large number of NEs.

1. Check whether the service traversed a large number of NEs.

  • If yes, perform rerouting. Alternatively, delete the original path and establish a new one.
  • If not, go to step 2.

2. Collect alarm information and configuration information, and then contact technical support personnel.