PM/4/EVT_PER_REP_UAT_NEW

Message

PM/4/EVT_PER_REP_UAT_NEW: The event starts at [StartTime], stops at [EndTime], and event state is [EventState] (InstanceTypeName=[InstanceTypeName], InstanceTypeId=[InstanceTypeId], InstanceName=[InstanceName], MeasureId=[MeasureId], MeasureName=[MeasureName]).

In VS mode, this log is supported only by the admin VS.

Description

UAT event information.

Parameters

Parameter Name Parameter Meaning

StartTime

Event start time

EndTime

Event end time

EventState

Event status

InstanceTypeName

Name of a statistical type

InstanceTypeId

ID of a statistical type

InstanceName

Name of a statistical instance

MeasureId

ID of a statistical indicator

MeasureName

Name of a statistical indicator

Possible Causes

Cause 1: The UAT event was generated when 10 SESs continuously occurred.

Cause 2: The UAT event was cleared when 10 non-SESs continuously occurred.

Procedure

  • Cause 1: The UAT event was generated when 10 SESs continuously occurred.

1. Check whether link signals are of poor quality. Replace the fiber or clean the optical module. Check whether the event is cleared.

  • If the event is cleared, the log message is informational only, and no action is required.
  • If the event is not cleared, go to 2.

2. Collect log information and configuration information, and then contact technical support personnel.

  • Cause 2: The UAT event was cleared when 10 non-SESs continuously occurred.
  • This log message is informational only, and no action is required.