LDT/4/hwAutoLoopDetectAlarm_active: The interface turned to trigger-down state,because of the loop detected on this interface. (Interface=[IfName], VlanId=[VlanId], InstName=[vsi_name])
In VS mode, this log is supported only by the admin VS.
The interface turned to the trigger-down state because a loop was detected on this interface.
Parameter Name | Parameter Meaning |
---|---|
IfName |
Interface name. |
VlanId |
VLAN ID. |
vsi_name |
VSI name. |
1.Run the display loop-detect trigger trigger-down all command to check whether there is an interface in the trigger-down state.
2.Check whether the interface connection has a loop.
3.After removing the interface loop, run the reset loop-detect trigger trigger-down command to unblock the interface, and check whether the alarm is released.
4.Collect alarm information, log information and configuration information, and then contact technical support personnel.
5.End.
1.Run the display loop-detect trigger trigger-down all command to check whether there is an interface in the trigger-down state.
2.Check whether loops occur on the interface and the Layer 2 network connected to the interface.
3.Collect trap, log, and configuration information, and contact technical support personnel.
4.End.