DEVM/1/hwBoardFail_active-132110

Message

DEVM/1/hwBoardFail_active: The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132110,Reason=The voltage exceeded the upper limit of the major threshold.)

In VS mode, this log is supported only by the admin VS.

Description

The board experienced a partial failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

-1: mpu(1)

-2: lpu(2)

-3: sfu(3)

-4: pic(4)

-5: cfcard(5)

-6: ofc(6)

-7: board(7)

-255: other(255)

EntityTrapFaultID

Indicates the error code.

Reason

Indicates the description of the cause of the trap.

Possible Causes

The voltage exceeded the upper limit of the major threshold.

Procedure

1. If the power module fails, first rectify the fault.

2. Run the display voltage slot slot-id command in the user view to check whether the actual voltage exceeds the upper major threshold.

3. If the actual voltage exceeds the upper major threshold, collect trap, log, and configuration information, and contact technical support.

4. End.