DEVM/1/hwBoardFail_active-132111

Message

DEVM/1/hwBoardFail_active: The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132111,Reason=The voltage was lower than the lower limit of the fatal threshold.)

This log is supported only on NetEngine 8000 F1A.

In VS mode, this log is supported only by the admin VS.

Description

The board experienced a partial failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity. The value can be one of the following:

-1: mpu(1)

-2: lpu(2)

-3: sfu(3)

-4: pic(4)

-5: cfcard(5)

-6: ofc(6)

-7: board(7)

-255: other(255)

EntityTrapFaultID

Indicates the error code.

Reason

Indicates the description of the cause of the trap.

Possible Causes

The voltage was lower than the lower limit of the fatal threshold.

Procedure

1. Run the display voltage slot slot-id command in the user view to check whether the actual voltage is lower than the lower critical threshold.

2. Check that the voltage of the external power supplier is adequate. Otherwise, increase the voltage of the external power supplier and check whether the alarm is cleared.

  • If the alarm is cleared, no action is required.
  • If the alarm persists, go to Step 3.

3. Replace the board and check whether the alarm is cleared.

  • If the alarm is cleared, no action is required.
  • If the alarm persists, go to Step 4.

4. Collect trap, log, and configuration information, and contact technical support.