DEVM/1/hwBoardFail_active: The board partially failed.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType],EntityTrapFaultID=132111,Reason=The voltage was lower than the lower limit of the fatal threshold.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the physical entity. |
EntityType |
Indicates the type of the physical entity. The value can be one of the following: -1: mpu(1) -2: lpu(2) -3: sfu(3) -4: pic(4) -5: cfcard(5) -6: ofc(6) -7: board(7) -255: other(255) |
EntityTrapFaultID |
Indicates the error code. |
Reason |
Indicates the description of the cause of the trap. |
1. Run the display voltage slot slot-id command in the user view to check whether the actual voltage is lower than the lower critical threshold.
2. Check that the voltage of the external power supplier is adequate. Otherwise, increase the voltage of the external power supplier and check whether the alarm is cleared.
3. Replace the board and check whether the alarm is cleared.
4. Collect trap, log, and configuration information, and contact technical support.