DEVM/2/hwBrdTempFatalAlarm_active-143874

Message

DEVM/2/hwBrdTempFatalAlarm_active: The board temperature exceeded the fatal alarm threshold. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName],EntityThresholdType=[EntityThresholdType], EntityThresholdCritical=[EntityThresholdCritical], EntityThresholdCurrent=[EntityThresholdCurrent], EntityTrapFaultID=143874, Reason=The fan temperature was extremely high.)

In VS mode, this log is supported only by the admin VS.

Description

Board temperature fatal alarm.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

EntityThresholdType

The abnormal type for temperature:

1: hige.

2: low.

EntityThresholdCritical

The critical alarm threshold for critical alarm.

EntityThresholdCurrent

The current value that been measured.

EntityTrapFaultID

To describe the fault id of trap.

Reason

Indicates the description of the cause of the trap.

Possible Causes

The fan temperature was extremely high.

Procedure

1. Check if the filter screen of the fan module is clogged. If the filter screen is clogged, clean the filter screen.

2. Check the ambient temperature. If the ambient temperature is too high, reduce the temperature to a normal level.

3. Check if the fan module is faulty. If there is a fault on the fan module, rectify the fault first.

4. If the ambient temperature is normal but the alarm is still reported, the possible cause is that the module temperature is too high. In this case, collect the information about alarms, logs, and configurations, and then contact technical support personnel.

5. End.