PIC/1/hwCardFail_active-135197

Message

PIC/1/hwCardFail_active: The card failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=135197, Reason=A voltage drop occurred on the board.)

In VS mode, this log is supported only by the admin VS.

Description

The subcard experienced a partial failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

EntityType

Indicates the type of the physical entity.

EntityTrapFaultID

Indicates the error code.

Reason

Indicates the description of the cause of the trap.

Possible Causes

A voltage drop occurred on the board.

Procedure

1. Check whether external power supply is normal.If a power supply problem exists, locate and resolve the problem.

2. Remove the associated board and insert it again. Check whether the board can successfully register. If the registration fails, replace the board.