CLKM/4/hwClockGnssModelChange: Switches the mode of the smart clock module. (hwClockPortIfIndex=[hwClockPortIfIndex], hwClockPortName=[hwClockPortName], hwClockGnssModel=[hwClockGnssModel], hwClockOldGnssModel=[hwClockOldGnssModel])
In VS mode, this log is supported only by the admin VS.
| Parameter Name | Parameter Meaning | 
|---|---|
| hwClockPortIfIndex | Index of the port whose working mode is changed. | 
| hwClockPortName | Name of the port whose working mode is changed. | 
| hwClockGnssModel | New working mode. The value can be: gps(1) glonass(2) beidou(3) gps-glonass(4) gps-beidou(5) | 
| hwClockOldGnssModel | Old working mode of the port. The value can be: gps(1) glonass(2) beidou(3) gps-glonass(4) gps-beidou(5) | 
Cause 1: The user manually changed the configuration to switch the GNSS mode.
Cause 2: The mode of the module is automatically switched based on the priority.
1. Run the display smart-clock command to check the current working mode and the number of working modes.
2. Collect trap, log, and configuration information, and contact technical support.
3. End.