CLKM/4/hwClockSourceFreqCheck_active

Message

CLKM/4/hwClockSourceFreqCheck_active: The check of frequence abnormal notification. (hwClockSrcCfgChassisIndex=[hwClockSrcCfgChassisIndex], hwClockSrcCfgSourceTypeIndex=[hwClockSrcCfgSourceTypeIndex], hwClockSrcCfgSourceIndex=[hwClockSrcCfgSourceIndex], hwClockChassisId=[hwClockChassisId], hwClockSrcCfgFreqCheckResult=[hwClockSrcCfgFreqCheckResult], hwClockSrcCfgSourceDescr=[hwClockSrcCfgSourceDescr])

In VS mode, this log is supported only by the admin VS.

Description

The frequency offset detection functioned abnormally.

Parameters

Parameter Name Parameter Meaning

hwClockSrcCfgChassisIndex

Indicates the index of the chassis where the non-PTP clock source is located. In the case of a single chassis, the index is 1. For a chassis where a PTP clock source is located, the index is invalid.

hwClockSrcCfgSourceTypeIndex

Index of the clock source type. values:

bits(1).

ptp(2).

interface(3).

cesacr(4).

hwClockSrcCfgSourceIndex

Index of the clock source.

hwClockChassisId

Chassis id.

hwClockSrcCfgFreqCheckResult

Result of the check of frequency, values:

abnormal(0).

normal(1).

hwClockSrcCfgSourceDescr

The description of clock source.

Possible Causes

The signals of the clock source were faulty.

Procedure

1. Run the display clock source command to check the current status of the clock source.

  • If the clock source is in the abnormal state, go to Step 2.
  • If the clock source is in the normal state, go to Step 5.

2. Run the display clock config command to check whether the frequency offset detection is enable.

  • If the frequency offset detection is enable, go to Step 3.
  • If the frequency offset detection is not enable, go to Step 5.

3. Run the clock freq-deviation recover command in the interface viewer to check whether the clock can be resumed.

  • If the clock can be resumed, go to Step 4.
  • If the clock can not be resumed, go to Step 5.

4. Check whether the alarm is cleared.

  • If the alarm is cleared, go to step 6.
  • If the alarm is not cleared, go to step 5.

5. Collect the trap information, log information, and configuration of the router, and contact Huawei technical personnel.

6. End.