CLKM/4/hwClockSourceSwitch: The clock source is switched. (hwClockChassisId=[hwClockChassisId], hwClockPllId=[hwClockPllId], hwClockLastSourceName=[hwClockLastSourceName], hwClockCurSourceName=[hwClockCurSourceName], hwClockSrcSelChassisIndex=[hwClockSrcSelChassisIndex], hwClockSrcSelType=[hwClockSrcSelType], hwClockSrcSelMode=[hwClockSrcSelMode])
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
hwClockChassisId |
ID of the chassis where the clock source is located. The value is fixed to 1 for a single chassis. |
hwClockPllId |
ID of the clock source type. The options are as follows:
|
hwClockLastSourceName |
Name of the clock source before the switching. |
hwClockCurSourceName |
Name of the current clock source. |
hwClockSrcSelChassisIndex |
Index of the chassis where the clock source is located. In the case of a single chassis, the value is fixed to 1. |
hwClockSrcSelType |
Type of the clock source. The value can be:
|
hwClockSrcSelMode |
Clock source selection mode. The value can be:
|
Cause 1: The attributes of the clock device on the network change. As a result, the current master clock is switched.
Cause 2: The link was faulty or the interface went down.
Cause 3: The clock source was manually switched in manual or force mode.
1. Run the display clock config command to check the running mode of the clock source.
2. Run the display clock config command to check the clock source selection mode.
3. Run the display clock source command to check whether the clock source status is normal.
4. Run the display clock source command to check whether the attributes of the clock source change.
5. Collect trap, log, and configuration information, and contact technical support.
6. End.