DEVM/2/hwCommunicateError_clear-140288

Message

DEVM/2/hwCommunicateError_clear: The communication channel resumed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapEntType=[EntityTrapEntType], EntityTrapFaultID=140288, EntityCommunicateType=[EntityCommunicateType], Reason=The channel monitoring module failed.)

In VS mode, this log is supported only by the admin VS.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntPhysicalName

The textual name of the physical entity.

EntityTrapEntType

The type of this entity.

EntityTrapFaultID

To describe the fault id of trap.

EntityCommunicateType

The type of this commnuicate.

The value can be:

1. Control channel:1.

2. monitor channel:2.

3. clock channel:3.

4. data channel:4.

Reason

Reason integer.

Possible Causes

The channel monitoring module failed.

Procedure

1.On the system installed with a single MPU, if the alarm persists, collect information about alarms, logs, and configurations, and then contact Huawei technical support personnel.

2.On the system installed with two MPUs, if the alarm persists on both MPUs, collect information about alarms, logs, and configurations, and then contact Huawei technical support personnel.

3.If the slave MPU fails and no master/slave switchover is performed, remove and then install the slave MPU. Then, go to Step 5.

4.If the master MPU fails and a master/slave switchover is performed, remove and then install the current MPU. Then, go to Step 5.

5.If the slave MPU cannot be registered or the failure cannot be rectified, replace the faulty board.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >