DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67594], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Cause1:A PMU was not detected. A PMU was removed or insecurely inserted. Cause2:The power supply module was not properly installed.The power supply module is absent.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
BaseTrapSeverity |
To describe the level of trap. |
ProbableCause |
To describe the probable cause of trap. |
BaseTrapEventType |
To describe the type of trap. |
EntityPhysicalIndex |
The index of the physical entity. |
EntContainedIn |
The value of entPhysicalIndex for the physical entity. |
EntPhysicalName |
The textual name of the physical entity. |
RelativeResource |
This object may contain a key word to indicate the relative resource of an entity. |
ReasonDescription |
To describe the reason of trap in DisplayString style. |
Cause1:A PMU was not detected. A PMU was removed or insecurely inserted.
Cause2:The power supply module was not properly installed.The power supply module is absent.
1. Check whether the power module is inserted completely. If the power module is in position, remove and insert the power module. Then, check whether the alarm is cleared.
3. Replace the power module and check whether the alarm is cleared.
4. Collect trap, log, and configuration information, and contact technical support.
5. End.