DEVM/1/hwEntityInvalid_active-67604

Message

DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67604], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=The communication of the Monitor bus failed. This trap indicates that the Monitor bus was faulty.)

In VS mode, this log is supported only by the admin VS.

Description

Physical entity failed.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

Possible Causes

The communication of the Monitor bus failed. This trap indicates that the Monitor bus was faulty.

Procedure

1. Run the power off and power on commands on the involved board. After the board is registered, check whether the alarm is cleared.

  • If so, go to Step 5.
  • If not, go to Step 2.

2. Remove the board and check whether the pinch board of the Monitor bus is installed well. Reinsert the board. Then, check whether the alarm is cleared.

  • If so, go to Step 5.
  • If not, go to Step 3.

3. Replace the board and check whether the alarm is cleared.

  • If so, go to Step 5.
  • If not, go to Step 4.

4. Collect trap, log, and configuration information, and contact technical support.

5. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >