DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67604], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=The communication of the Monitor bus failed. This trap indicates that the Monitor bus was faulty.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
BaseTrapSeverity |
To describe the level of trap. |
ProbableCause |
To describe the probable cause of trap. |
BaseTrapEventType |
To describe the type of trap. |
EntityPhysicalIndex |
The index of the physical entity. |
EntContainedIn |
The value of entPhysicalIndex for the physical entity. |
EntPhysicalName |
The textual name of the physical entity. |
RelativeResource |
This object may contain a key word to indicate the relative resource of an entity. |
ReasonDescription |
To describe the reason of trap in DisplayString style. |
The communication of the Monitor bus failed. This trap indicates that the Monitor bus was faulty.
1. Run the power off and power on commands on the involved board. After the board is registered, check whether the alarm is cleared.
2. Remove the board and check whether the pinch board of the Monitor bus is installed well. Reinsert the board. Then, check whether the alarm is cleared.
3. Replace the board and check whether the alarm is cleared.
4. Collect trap, log, and configuration information, and contact technical support.
5. End.