DEVM/1/hwEntityInvalid_active-67631

Message

DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67631], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Output voltage of the DC power supply module was abnormal.)

In VS mode, this log is supported only by the admin VS.

Description

Physical entity failed.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

Possible Causes

Output voltage of the DC power supply module was abnormal.

Procedure

1. Check whether the power supply is powered on.

  • If yes, go to step 3.
  • If no, go to step 2.

2. Set the switch to ON and check whether the alarm persists.

  • If yes, go to step 3.
  • If no, go to step 5.

3. Replace the power module. Power off the faulty power module before replacing it.

Check whether the alarm is cleared.

  • If yes, go to step 5.
  • If no, go to step 4.

4. Collect trap, log, and configuration information, and contact Huawei technical support personnel.

5. End.