DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67660], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Cause1:The second 48 V power supply failed: The second power module was not installed or The second power module failed. Cause2:One or both power supplies failed,No external power supply was available for one or both power modules. Cause3:The two PMU monitor buses failed.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
BaseTrapSeverity |
To describe the level of trap. |
ProbableCause |
To describe the probable cause of trap. |
BaseTrapEventType |
To describe the type of trap. |
EntityPhysicalIndex |
The index of the physical entity. |
EntContainedIn |
The value of entPhysicalIndex for the physical entity. |
EntPhysicalName |
The textual name of the physical entity. |
RelativeResource |
This object may contain a key word to indicate the relative resource of an entity. |
ReasonDescription |
To describe the reason of trap in DisplayString style. |
Cause1:The second 48 V power supply failed:
The second power module was not installed or The second power module failed.
Cause2:One or both power supplies failed,No external power supply was available for one or both power modules.
Cause3:The two PMU monitor buses failed.
The second 48 V power supply failed.
1. Run the display device command and check whether the second power supply is unavailable.
2. Install an additional power module and check whether the trap is cleared.
3. Run the display device command and check whether the power module works properly.
4. Replace the faulty power module and check whether the alarm is cleared.
5. Collect trap, log, and configuration information, and contact technical support.
6. End.