DEVM/1/hwEntityInvalid_active-67660

Message

DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67660], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Cause1:The second 48 V power supply failed: The second power module was not installed or The second power module failed. Cause2:One or both power supplies failed,No external power supply was available for one or both power modules. Cause3:The two PMU monitor buses failed.)

In VS mode, this log is supported only by the admin VS.

Description

Physical entity failed.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

Possible Causes

Cause1:The second 48 V power supply failed:

The second power module was not installed or The second power module failed.

Cause2:One or both power supplies failed,No external power supply was available for one or both power modules.

Cause3:The two PMU monitor buses failed.

Procedure

The second 48 V power supply failed.

1. Run the display device command and check whether the second power supply is unavailable.

  • If so, go to Step 2.
  • If not, go to Step 3.

2. Install an additional power module and check whether the trap is cleared.

  • If so, go to Step 6.
  • If not, go to Step 3.

3. Run the display device command and check whether the power module works properly.

  • If so, go to Step 5.
  • If not, go to Step 4.

4. Replace the faulty power module and check whether the alarm is cleared.

  • If so, go to Step 6.
  • If not, go to Step 4.

5. Collect trap, log, and configuration information, and contact technical support.

6. End.