DEVM/1/hwEntityInvalid_active-67849

Message

DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67849], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=The channel between pannel eth0 of ICUs became faulty.)

In VS mode, this log is supported only by the admin VS.

Description

The control channel between physical entities is faulty.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity which 'contains' this physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

Possible Causes

The channel between pannel eth0 of ICUs became faulty.

Procedure

1. Check whether the LEDs of corresponding interfaces on the ICU blink. If the cable is correctly connected but the LEDs do not blink, replace the network cable and check whether the alarm is cleared. If the alarm persists, perform the next step.

2. Replace the board and check whether the alarm is cleared. If it is not cleared, perform the next step.

3. Collect log files and contact Huawei technical support personnel.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >