DEVM/1/hwEntityInvalid_active-67851

Message

DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67851], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=A loop is formed between ICU(s), either because two connections are established between ICUs or two ports of the same ICU are interconnected.)

In VS mode, this log is supported only by the admin VS.

Description

The control channel between physical entities is faulty.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity which 'contains' this physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

Possible Causes

A loop is formed between ICU(s), either because two connections are established between ICUs or two ports of the same ICU are interconnected.

Procedure

1. View the EntPhysicalName field in alarm information. Check which two interfaces form a ring.

2. Remove the cables of the corresponding interfaces. Note that the alarm generated when the device is started with a ring will not be cleared after the ring is broken. You must run a command to clear the alarm or restart the device.

3. Connect the cables as specified.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >