DEVM/1/hwEntityInvalid_active-67852

Message

DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67852], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=Two MPUs of a CLC were connected to the same ICU.)

In VS mode, this log is supported only by the admin VS.

Description

The control channel between physical entities is faulty.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity which 'contains' this physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

Possible Causes

Two MPUs of a CLC were connected to the same ICU.

Procedure

1. View the EntPhysicalName field in alarm information. Check which two MPUs in the CLC chassis are connected to the same ICU.

2. Connect one of the two MPUs in the CLC to the other ICU.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >