DEVM/1/hwEntityInvalid_active-68060

Message

DEVM/1/hwEntityInvalid_active: Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[68060], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=The fault in the key chip of the PIC card was detected.)

In VS mode, this log is supported only by the admin VS.

Description

Physical entity failed.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

Possible Causes

The fault in the key chip of the PIC card was detected.

Procedure

1. Check whether the faulty board is an FPIC.

  • If so, go to Step 3.
  • If not, go to Step 2.

2. Run the reset slot slotID card cardID command to reset the FPIC, and then check whether the alarm is cleared.

  • If so, go to Step 6.
  • If not, go to Step 3.

3. Run the reset slot slotID command to reset the faulty board and then check whether the board can function properly.

  • If so, go to Step 6.
  • If not, go to Step 4.

4. Replace the faulty board. After the new board is registered, check whether the alarm is cleared.

  • If so, go to Step 6.
  • If not, go to Step 5.

5. Collect trap, log, and configuration information, and contact technical support.

6. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.