DEVM/1/hwEntityReset_active-66576

Message

DEVM/1/hwEntityReset_active: Physical entity reset. (EntityPhysicalIndex=[ULONG],BaseTrapSeverity=4, BaseTrapProbableCause=66576, BaseTrapEventType=5, EntityPhysicalIndex=[ULONG], EntPhysicalContainedIn=[ULONG], EntPhysicalName=[STRING], RelativeResource=[STRING], ReasonDescription=Because of heart beat loss, the entity of %s is resetting, not ready.)

In VS mode, this log is supported only by the admin VS.

Description

The physical entity reset because a part failed.

Parameters

Parameter Name Parameter Meaning

BaseTrapSeverity

Indicates the physical index.

BaseTrapProbableCause

Possible reason.

BaseTrapEventType

Indicates the possible cause of the trap.

EntityPhysicalIndex

Indicates the trap type.

EntPhysicalContainedIn

Indicates the parent index.

EntPhysicalName

Indicates the name of the entity such as a chassis.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

Possible Causes

Cause 1: A fault may occur on the ECM channel.

Cause 2: The CPU usage on the master MPU is too high.

Procedure

1. The interface board can be reset automatically. After the reset, run the display device command to check whether the interface board works normally.

  • If so, go to Step 4.
  • If not, go to Step 2.

2. Replace the interface board and then check whether the fault is rectified.

  • If so, go to Step 4.
  • If not, go to Step 3.

3. Collect the trap information, log information, and configuration of the router, and contact technical support personnel.

4. End.