DEVM/1/hwFanInvalid_active: The fan module failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalIndex |
The index for this entry. |
EntPhysicalName |
The textual name of the physical entity. |
EntityTrapFaultID |
To describe the fault id of trap. |
Reason |
Reason. |
1.Check whether the fan module is properly installed:
2. Collect the information about alarms, logs, and configurations, and then contact technical support personnel.
3. End.
1. Plugging in the cable.
2. If the alarm persists, collect alarm information, log information and configuration information, and then contact technical support personnel.
3. End.
1. Replace the fan module with a fan module that matches the chassis.
2. If the alarm persists, collect alarm information, log information and configuration information, and then contact technical support personnel.
3. End.
1. Check whether the 48 V power supply for the boards in the other slots is normal.
Two 48V power modules in backup mode supply power to fans.
2. If so, replace the fan module.
3. If there is an alarm of abnormal 48 V power supply on another board, refer to the handling procedure in hwPowerInvalid_136960.
4. If the alarm persists, collect alarm information, log information and configuration information, and then contact technical support personnel.
5. End.
1. Remove the fan module and insert it again.
2. If the alarm persists, collect alarm information, log information and configuration information, and then contact technical support personnel.
3. End.
1. Collect the information about alarms, logs, and configurations, and then contact technical support personnel.
2. End.
1. Change the fan module.
2. If the alarm persists, collect alarm information, log information and configuration information, and then contact technical support personnel.
3. End.
1. Remove and re-install the problem fan module. Then, check whether the alarm is cleared.
2. Swap the slot of the problem fault module with that of a normal fan module. Then, check whether the alarm is cleared.
3. Replace the problem fan module. Then, check whether the alarm is cleared.
4. Contact technical support personnel and provide them with collected logs.
5. End.
1. Remove and re-install the problem fan module. Then, check whether the alarm is cleared.
2. Swap the slot of the problem fault module with that of a normal fan module. Then, check whether the alarm is cleared.
3. Replace the problem fan module. Then, check whether the alarm is cleared.
4. Contact technical support personnel and provide them with collected logs.
5. End.
1. Remove and insert the fan module to check whether the alarm is cleared.
2. If the alarm persists, collect alarm information, log information and configuration information, and then contact technical support personnel.
3. End.
1.Change the fan module and check whether the alarm is cleared.
2.Collect alarm information, log information and configuration information, and then contact technical support personnel.
3.End.
1.Change the fan module and check whether the alarm is cleared.
2.Collect alarm information, log information and configuration information, and then contact technical support personnel.
3.End.
1.Change the fan module and check whether the alarm is cleared.
2.Collect alarm information, log information and configuration information, and then contact technical support personnel.
3.End.
1.Change the fan module and check whether the alarm is cleared.
2. If the alarm persists, collect alarm information, log information and configuration information, and then contact technical support personnel.
3. End.