DEVM/1/hwFanInvalid_active: The fan module failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=139272, Reason=The first 48V power supply of the fan module is faulty.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalIndex |
The index for this entry. |
EntPhysicalName |
The textual name of the physical entity. |
EntityTrapFaultID |
To describe the fault id of trap. |
Reason |
Reason. |
1. Remove and re-install the problem fan module. Then, check whether the alarm is cleared.
2. Swap the slot of the problem fault module with that of a normal fan module. Then, check whether the alarm is cleared.
3. Replace the problem fan module. Then, check whether the alarm is cleared.
4. Contact technical support personnel and provide them with collected logs.
5. End.