DEVM/1/hwFanInvalid_active-139273

Message

DEVM/1/hwFanInvalid_active: The fan module failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=139273, Reason=The second 48V power supply of the fan module is faulty.)

In VS mode, this log is supported only by the admin VS.

Description

The fan function is disabled.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntPhysicalName

The textual name of the physical entity.

EntityTrapFaultID

To describe the fault id of trap.

Reason

Reason.

Possible Causes

The second 48V power supply of the fan module is faulty.

Procedure

1. Remove and re-install the problem fan module. Then, check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 5.
  • If the alarm persists, go to Step 2.

2. Swap the slot of the problem fault module with that of a normal fan module. Then, check whether the alarm is cleared.

  • If the problem fan module still reports the alarm in the new slot, go to Step 3.
  • If the slot housing the problem fan module reports the alarm, go to Step 4.

3. Replace the problem fan module. Then, check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 5.
  • If the alarm persists, go to Step 4.

4. Contact technical support personnel and provide them with collected logs.

5. End.