DRIVER/2/hwFlexEPhyFcsSdAlarm_active

Message

DRIVER/2/hwFlexEPhyFcsSdAlarm_active: The FCS-SD error is rising.(hwPhysicalPortIfIndex=[hwPhysicalPortIfIndex], hwPhysicalPortName=[hwPhysicalPortName])

In VS mode, this log is supported only by the admin VS.

Description

The FCS-SD error is rising.

Parameters

Parameter Name Parameter Meaning

hwPhysicalPortIfIndex

Index of physical port.

hwPhysicalPortName

Name of physical port.

Possible Causes

The FlexE physical interface receives fcs-sd data.

Procedure

1. Check whether the optical fiber is properly connected. The optical fiber has card fasteners. If you hear a click sound, the optical fiber is properly connected. Then, run the display this interface command to check whether the interface is Up.

  • If so, go to Step 2.
  • If not, go to Step 3.

2. Run the display this interface command in the interface view to check whether the receive optical power of the optical module is in the normal range.

  • If so, go to Step 3.
  • If not, go to Step 3.

3. Collect alarm information, log information and configuration information, and then contact technical support personnel.

4. End.

Copyright © Huawei Technologies Co., Ltd.